Pyruvic Acid SDS MSDS of Manufacturers Exporters
Aadhunik Industries is a manufacturing group company. Aadhunik Industries is pioneer manufacturers of Pyruvic Acid, Specialty Chemicals, Pharmaceutical Excipients, Food Fragrance & Flavor chemicals in India. It has toll manufacturers and representatives in UAE, Europe, Canada & USA and agents & customers in all countries like USA, Canada, Europe, UAE, South Africa, Tanzania, Kenya, Egypt, Nigeria, Uganda, Turkey, Mexico, Brazil, Chile, Argentina, Dubai, Netherlands, Italy, Spain, Germany, Portugal, France, Malaysia, Indonesia, Thailand, Korea, Japan, Russia etc. Aadhunik Industries and/or associated units are FDA-GMP certified, Halal and/or Kosher certified, REACH registered, ISO-9001, ISO-22000 HACCP certified. We offer crystals granules in precise micron or mesh size as per buyers needs. We offer very high purity standards as per specifications required. ---------- ---------- Translate
127-17-3, EINECS EC Number: 204-824-3, Molecular Formula: CH3COCOOH or C3H4O3, Molecular Weight: 88.06
Specifications of Pyruvic Acid Manufacturers
Pyruvic acid or α-Ketopropionic acid or 2-Oxopropionic acid
SDS Safety Data Sheet
MSDS, Material Safety Data SheetSection 1: Product Identification
Product Name & Other Names: Pyruvic acid or α-Ketopropionic acid or 2-Oxopropionic acid.
CAS No.: 7664-38-2
EINECS EC Number: 127-17-3
Molecular Weight: 88.06
Chemical Formula: CH3COCOOH or C3H4O3
Relevant identified uses of the substance or mixture and uses advised against: Laboratory chemicals, Manufacture of substances. For Industrial use.Section 2: Hazard Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008Skin corrosion/irritation Category 1A, B, C, H314
Labeling according to Regulation (EC) No 1272/2008
GHS Label Elements
CorrosiveSignal Words: Danger
Hazard statements:
H314: Causes severe skin burns and eye damage.Precautionary statements:
P234: Keep only in original container.
P260: Do not breathe dust/fume/gas/mist/vapors/spray.
P264: Wash … thoroughly after handling.
P280: Wear protective gloves/protective clothing/eye protection/face protection.
P312: Call a POISON CENTER or doctor/physician if you feel unwell.
P362: Take off contaminated clothing and wash before reuse.
P303+361+353: IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P305+351+338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do – continue rinsing.
P501: Dispose of contents/container to authorized agents only.Classification according to EU Directives 67/548/EEC or 1999/45/EC:
Hazard Symbol:
C Corrosive
Risk Phrases:
R35 Causes severe burns.
R41 Risk of serious damage to eyes.Section 3: Composition / Information on Ingredients
Product Name & Other Names: Pyruvic acid or α-Ketopropionic acid or 2-Oxopropionic acid.
CAS No.: 7664-38-2
EINECS EC Number: 127-17-3Section 4: First Aid Measures
Always seek medical attention after first aid measures are provided.
Eye Contact: Check for and remove any contact lenses. In case of contact, immediately flush eye with plenty of water for at least 15 minutes. Cold water may be used. Get medical attention immediately.
Skin Contact: Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Call a physician, immediately. Wash clothing before reuse.
Ingestion: If swallowed, do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to and unconscious person. Loosen tight clothing such as a collar, tie, belt, or waistband. Get medical attention immediately.
Inhalation: If inhaled If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.Section 5: Fire Fighting Measures
Flash Point: 82C.
Fire Extinguishing Media: Adapt extinguishing media to the environment. Use water spray, alcohol-resistant foam, dry chemical, or carbon dioxide.
Hazardous combustion products: Oxides of carbon and fumes.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes. Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used.Section 6: Accidental Release Measures
Personal precautions, protective equipment, and emergency procedures: Ventilate area of leak or spill. Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material. Eliminate any ignition sources.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment Cleanup procedures and Storage: Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g., sand, earth, diatomaceous earth, vermiculite). Vacuum or sweep-up and remove to an approved disposal container. Small quantities of liquid spill may be neutralized with soda-ash solution. Wash away neutralized product with plentiful water.Section 7: Handling and Storage
Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like strong oxidizing agents, strong bases.Section 8: Exposure Controls / Personal Protection
Components with workplace control parameters: No data available.
Engineering Controls Ventilation required: It should be handled or transferred in an approved fume hood or with adequate ventilation.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion into the work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full-face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards.Section 9: Physical and Chemical Properties
Appearance and Physical State: Colorless to light yellowish liquid.
Odor: Not available.
Odor threshold: Not available.
pH: Acidic.
Relative density: about 1.27
Melting Point: 12C to 13C literature.
Boiling Point: 165C literature.
Flash point: 82C.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor Pressure (mm Hg): Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility in Water: Miscible with water. Soluble in organic solvents, oils.
Viscosity: Not available.Section 10: Stability and Reactivity
Stability: It is stable under ordinary conditions of use and storage.
Materials to Avoid (Incompatibility): Strong bases, Oxidizing agents, Powdered metals. Possibility of hazardous reactions Violent reactions possible with alkalis, oxidizing agents and reducing agents.
Hazardous Decomposition Products: Thermal decomposition may produce carbon and fumes.
Hazardous Polymerization: Will not occur.Section 11: Toxicological Information
Results of component toxicity test:
LD50 Subcutaneous Mouse: 3.533 mg/kg.
Carcinogenicity: This product is not classifiable as to its carcinogenicity based on its IARC, ACGIH, NTP, or EPA classification.
Mutagenic Effects: Not available.
Developmental Toxicity: Not available.
Reproductive Effects: No information available.Section 12: Ecological Information
Toxicity to fish: No information available.
Persistence and Degradability: Unlikely to persist due to water solubility.
Mobility: Likely to be mobile due to water solubility.
Results of PBT and vPvB assessment: This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.Section 13 Disposal Considerations
State and local laws governing disposal of materials can differ. Ensure proper disposal compliance with proper authorities before disposal. Dispose as per law.
Section 14: Transportation Information
DOT USA, TDG Canada & ADR/RID Europe:
Proper shipping name: Corrosive liquid, acidic, organic, n.o.s. (pyruvic acid).
Hazard Class: 8, Packaging group: II, UN Number: UN3265
IMO/IMDG & IATA:
Proper shipping name: Corrosive liquid, acidic, organic, n.o.s. (pyruvic acid).
Hazard Class: 8, Packaging group: II, UN Number: UN3265Section 15: Regulatory Information
USA:
SARA Section 311/312 Hazard Classes: See section 2.
California Proposition 65: Not listed.Section 16: Other Information
European Labeling in Accordance with EC Directives:
H314: Causes severe skin burns and eye damage.Disclaimer:
**************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
**************************CAS Number 7664-38-2, Pyruvic Acid or α-Ketopropionic acid or 2-Oxopropionic acid manufacturers suppliers exporters at:
manufacturer supplier exporter
Aadhunik Industries
Ankleshwar Gujarat & Mumbai, India
TEL: (OFFICE) 91-22-23774610, 23723564.e-mail: info@aadhunikindustries.com
Copyright and Usual Disclaimer is Applicable. 8-12-2022